Wearable Skin Patch Monitors Hemoglobin in Deep Tissues


the health strategist

institute for 
strategic health transformation


Joaquim Cardoso MSc.

Chief Research & Strategy Officer (CRSO),
Chief Editor and Senior Advisor


August 28, 2023


What is the message?


Researchers at UC San Diego have developed a wearable skin patch equipped with a photoacoustic sensor that can monitor hemoglobin and potentially core temperature in deep tissues. 


  • This wearable patch offers a noninvasive and comfortable solution for continuous monitoring of biomolecules, enabling early diagnosis of conditions such as tumors, organ malfunction, and hemorrhages. 

The patch’s innovative technology overcomes limitations of existing methods like MRI and X-ray by providing long-term monitoring with high spatial resolution and safety due to its use of low-power laser pulses. 


The development of this technology could have significant clinical applications and potential benefits for patient care. 

The research was supported by various grants from organizations like the Air Force Research Laboratory and the National Institutes of Health.



Wearable Skin Patch Monitors Hemoglobin in Deep Tissues


A photoacoustic sensor could help clinicians diagnose tumors, organ malfunction and more


UC San Diego
Emerson Dameron
December 16, 2022


Low blood perfusion inside the body may cause severe organ dysfunctions and is associated with a range of ailments, including heart attacks and vascular diseases of the extremities. At the same time, abnormal blood accumulation in areas such as in the brain, abdomen or cysts can indicate cerebral or visceral hemorrhage or malignant tumors. Continuous monitoring can aid diagnosis of these conditions and help facilitate timely and potentially life-saving interventions.


The new sensor overcomes some significant limitations in existing methods of monitoring biomolecules. Magnetic resonance imaging (MRI) and X-ray-computed tomography rely on bulky equipment that can be hard to procure and usually only provide information on the immediate status of the molecule, which makes them unsuitable for long-term biomolecule monitoring.


“Continuous monitoring is critical for timely interventions to prevent life-threatening conditions from worsening quickly,” said Xiangjun Chen, a nanoengineering PhD student in the Xu group and study co-author. “Wearable devices based on electrochemistry for biomolecules detection, not limited to hemoglobin, are good candidates for long-term wearable monitoring applications. However, the existing technologies only achieve the ability of skin-surface detection.”


The new, flexible, low form-factor wearable patch comfortably attaches to the skin, allowing for noninvasive long-term monitoring. It can perform three-dimensional mapping of hemoglobin with a submillimeter spatial resolution in deep tissues, down to centimeters below the skin, versus other wearable electrochemical devices that only sense the biomolecules on the skin surface. It can achieve high contrast to other tissues. Due to its optical selectivity, it can expand the range of detectable molecules, integrating different laser diodes with different wavelengths, along with its potential clinical applications.


The patch is equipped with arrays of laser diodes and piezoelectric transducers in its soft silicone polymer matrix. Laser diodes emit pulsed lasers into the tissues. Biomolecules in the tissue absorb the optical energy, and radiate acoustic waves into surrounding media.


“Piezoelectric transducers receive the acoustic waves, which are processed in an electrical system to reconstruct the spatial mapping of the wave-emitting biomolecules”, said Xiaoxiang Gao, a postdoctoral researcher in Xu’s lab and co-author of the study.


“With its low-power laser pulses, it is also much safer than X-ray techniques that have ionizing radiation”, said Hongjie Hu, a postdoctoral researcher in the Xu group and study coauthor.


Based on its success so far, the team plans to further develop the device, including shrinking the backend controlling system to a portable-sized device for laser diode driving and data acquisition, greatly expanding its flexibility and potential clinical utility.


They also plan to explore the wearable’s potential for core temperature monitoring. “Because the photoacoustic signal amplitude is proportional to the temperature, we have demonstrated core temperature monitoring on ex-vivo experiments,” Xu said. “However, validating the core temperature monitoring on the human body requires interventional calibration.”


They are continuing to work with physicians to pursue more potential clinical applications.


The work was supported in part by Air Force Research Laboratory under agreement number FA8650–18–2–5402, and the National Institutes of Health grants 1R21EB025521–01 (S.X.), 1R21EB027303–01A1 (S.X.), and 3R21EB027303–02S1 (S.X.).



Coauthors include 

  • Xiaoxiang Gao *, Department of Nanoengineering, UC San Diego; 
  • Xiangjun Chen *, Materials Science and Engineering Program, UC San Diego; 
  • Hongjie Hu *, 
  • Xinyu Wang and 
  • Wentong Yue, Department of Nanoengineering, UC San Diego; 
  • Jing Mu, Materials Science and Engineering Program; 
  • Zhiyuan Lou and 
  • Ruiqi Zhang Department of Nanoengineering, UC San Diego; 
  • Keren Shi, Materials Science and Engineering Program, UC San Diego and Materials Science and Engineering Program, UC Riverside; 
  • Xue Chen, Materials Science and Engineering Program, UC San Diego; 
  • Muyang Lin, 
  • Baiyan Qi and 
  • Sai Zhou, Department of Nanoengineering, UC San Diego; 
  • Chengchangfeng Lu, 
  • Yue Gu and 
  • Xinyi Yang, Department of Electrical and Computer Engineering, UC San Diego; 
  • Hong Ding, 
  • Yangzhi Zhu, 
  • Hao Huang, 
  • Yuxiang Ma and 
  • Mohan Li, Department of Nanoengineering, UC San Diego; 
  • Aditya Mishra, Materials Science and Engineering Program, UC San Diego; 
  • Joseph Wang, Department of Nanoengineering and Materials Science and Engineering Program, UC San Diego; and 
  • Sheng Xu, Department of Nanoengineering, Department of Electrical and Computer Engineering, Materials Science and Engineering Program and Department of Bioengineering, UC San Diego; Department of Radiology, School of Medicine, UC San Diego; and Softsonics, Inc.

Originally published at https://today.ucsd.edu.

Total
0
Shares
Deixe um comentário

O seu endereço de e-mail não será publicado. Campos obrigatórios são marcados com *

Related Posts

Subscribe

PortugueseSpanishEnglish
Total
0
Share